ROKONET Upload/Download by Rokonet. Versions: 3.1 and 2.0. File name: Orbit.exe. User manual Orbit Manufacturing Rokonet ORBIT-6 RP. MS Lock Upload/Download Software Upload/Download Programming. U/D software, to the Orbit-6. Samp Gamemodes Rp.

• INSTALLER MANUAL VER. B Installer Manual. • The ORBIT-6 (Model RP-206) complies with FCC Part 68 Rules. On the upper panel of this product is a label that contains, among other information, the FCC Registration Number and Ringer Equivalence Number (REN is 0.8B). If requested, this information must be provided to the Telephone Company. • Copyright © 2001 by Rokonet Ltd., 14 Hachoma Street Rishon Letzion 75655 Israel All rights reserved. No part of this document may be reproduced in any form without prior written permission from the publisher.

5IN206IM B Installer Manual. • Summary of User’s Commands It is necessary to ARM your system to obtain protection from intrusion. All other forms of protection, including fire and 24-hour panic alarms (i.e. Police, fire, and medical) are always ready to report alarms and do NOT need to be armed.

FUNCTION System Arming Stay Home Arming. • TABLE OF CONTENTS Introduction to the ORBIT-6.6 Main Features.6 Installation.7 Before You Begin. Free Download Orange Songs Doregama on this page. 7 Technical Data.8 Installer Programming.9 The keypad.9 Restoring Factory Defaults to the ORBIT-6.9 Introduction to Programming.9 Programming your Orbit-6. 10 Viewing the Contents of a Location. 11 Locations Whose Contents Occupy More Than One Digit. • INTRODUCTION TO THE ORBIT-6 The ORBIT-6 is intended to address the needs of many homes, offices, and small businesses. Its operation is designed around microprocessor and EEPROM (Electrically Erasable Programmable Read-Only Memory) technology, which stores, without the need for a source of power, the system’s operating program and its programmable parameters.

• INSTALLATION Before You Begin Be sure the actual work is performed by experienced personnel, licensed to carry out security system installations and capable of implementing all applicable requirements of the National Fire Protection Association (NFPA-70 and NFPA-74), as well as any federal, state, and local codes–along with any safety guidelines and regulations which might apply. • TECHNICAL DATA Main Panel Input power Rechargeable standby battery Auxiliary Power Bell/LS Sounder output Programmable output Cabinet Dimensions: Weight Main Board (dimensions / weight): Fuse F1 Fuse F2 Fuse F3 Keypads Current consumption: Control panel connections: Dimensions: Weight: Utility Output Expansion Module Current consumption: Control panel connections: Contacts. • INSTALLER PROGRAMMING The keypad Restoring Factory Defaults to the ORBIT-6 1. Your ORBIT-6 and at least one LED Keypad should already be wired together and/or physically installed 2.

Remove all power from the Printed Circuit 3. Dude Descending A Staircase Rar. Place the ORBIT-6’s J1 (DEFAULT) jumper over both corresponding pins. (See Figures 1A and 1B on page 32 and 33 ). • Programming your Orbit-6 Programming Methods Local LED or LCD keypads Orbit Programmer Easy programming of the control panel parameters with menu driven LCD display. The programmer can store up to 10 Orbit-6 programming sets and copy it directly to the panel.

The programmer supports both the Orbit-5 and Orbit-6 panels. • Viewing the Contents of a Location It’s often necessary to check the data stored in a memory location to be sure it’s correct. If improper data is found, it must be corrected in order to obtain the desired system response. The data in a location can either be a number (from 0-9) or a letter (from A-F). • Locations Whose Contents Occupy More Than One Digit When a location contains more than one digit, they cannot be viewed simultaneously. As soon as a location is accessed, the first digit is displayed automatically.

Additional digits (if they exist) can be displayed by pressing the following keys: Used to display the next digit in a location containing at least two digits. • Operation Action Enter the enter the factory default Installer Installer Code (0-2-0-6); Programming followed by # mode Access the press [0], [8], [ARM] current Installer Code (stored in location “08”) Enter a unique enter [3], [0], [5], [7] Installer Code (for this tutorial, we’ll use 3-0-5-7) Store the data. • GENERAL SYSTEM PARAMETERS: LOCATIONS 00–05 Location: 00 Default Enable: Def: 00 PURPOSE: to enable or disable the option of resetting the system to the factory defaults. Enable the option of resetting the system to the factory defaults. Disable the option of resetting the system to the factory defaults. Location: 01 MS Lock: Def: 000000 §. • Location: 04 Callback UD Phone # Enables greater security for remote Upload/Download operation.

This is a number to which the alarm company computer, equipped with the U/D software, will be connected. When a call is made from a computer, using U/D software, to the Orbit-6 panel, the system will hang-up and call back using this UD phone number.